Execution of Structural Fire Protection

Effective Fire Protection for Buildings, Installations and Employees

With the right structural fire protection, you can avoid potential risks, comply with legal requirements and take important precautions for your employees, buildings and installations. Our fire protection services meet the highest safety standards and prevent the rapid spread of smoke and fire.

Fire Protection for Electrical Installations

Coatings for Cables
Intumescent coating for cables and cable support structures, providing up to 30 minutes fire resistance in accordance with DIN 4102, meeting the required fire resistance class and system specification.

E-Enclosure 90/30
Construction of cable ducts ensuring functional integrity, executed as E30–E90 in accordance with DIN 4102, meeting the required fire resistance class and system specification.

I-Enclosure 30/90
Construction of installation ducts for cables and pipes, executed as I30–I90 in accordance with DIN 4102, meeting the required fire resistance class and system specification.

Fire Protection for HVAC Systems – Heating, Ventilation, Air Conditioning and Sanitation

Sealing
Fire protection for single cables and cable bundles, combustible pipes (up to 50 mm diameter) and non-combustible pipes with non-combustible mineral wool (melting point above 1,000 °C) and intumescent material, executed as R90 in accordance with DIN 4102, meeting the required fire resistance class and system specification.

Pipe Collars
Fire sealing of combustible pipes in walls and ceilings, executed as R90 in accordance with DIN 4102, meeting the required fire resistance class and system specification.

Sprinkler Supply Line
Fire protection cladding for sprinkler supply lines using fire protection boards or pipe sections, executed as F90 in accordance with DIN 4102, meeting the required fire resistance class and system specification.

Lindner Fireport EI 90
The first combination seal successfully tested according to EN 1366-3 for raised floor cavities/system floors. General construction approval Z-19.53-2423.

Fire Protection for Ventilation Systems – Smoke Extraction and Ductwork

Suspension and Fastening Systems
Usage of exclusively approved fastening systems in structural fire protection.

Mortared Fire Dampers
Sealing of wall and ceiling penetrations using mortar of group III (DIN 1053), executed as F90 in accordance with the required fire resistance class and system specification.

Smoke Extraction Duct L90
Construction of horizontal and vertical smoke extraction ducts (MRA), executed as L90 in accordance with DIN 4102, meeting the required fire resistance class and system specification.

Independent Ventilation Ducts L90
Construction of self-supporting horizontal and vertical ventilation ducts, executed as L30–L120 in accordance with DIN 4102, meeting the required fire resistance class and system specification. 

Plastic Ventilation Ducts L120
Cladding of horizontal and vertical plastic ventilation ducts, executed as L30–L120 in accordance with DIN 4102, meeting the required fire resistance class and system specification

Steel Sheet Ventilation Ducts L120
Cladding of horizontal and vertical steel sheet ventilation ducts, executed as L30–L120 in accordance with DIN 4102, meeting the required fire resistance class and system specification.

Fire Protection for Load-Bearing Structures – Steel Construction & Coating Systems

Cladding for Columns and Beams
Cladding of steel columns and beams with fire protection mats, executed as F30-A to F180-A in accordance with DIN 4102, meeting the required fire resistance class and system specification.

Coatings
Intumescent coating to meet the regulatory requirements for fire-resistant components, executed as F30 in accordance with DIN 4102, meeting the required fire resistance class and system specification.

Fire Protection for Ceilings, Walls & Shafts – Fire Resistance According to DIN 4102

Free-Spanning Fire-Resistant Ceilings
Construction of free-spanning fire-resistant ceilings (subject to fire exposure from above and below) using fire protection boards, executed as F30-AB to F90-AB in accordance with DIN 4102, meeting the required fire resistance class and system specification.

Suspended Fire-Resistant Ceilings
Construction of suspended fire-resistant ceilings (subject to fire exposure from above and below) using fire protection boards, executed as F30-A to F90-A in accordance with DIN 4102, meeting the required fire resistance class and system specification.

Shaft and Partition Walls
Cladding of shaft and partition walls (subject to fire exposure from above and below) using fire protection boards, executed as F90-A in accordance with DIN 4102, meeting the required fire resistance class and system specification.

Fire Protection for Construction Joints

Sealant
Sealing of expansion joints and flexible connection joints, executed as F90 in accordance with DIN 4102, meeting the required fire resistance class and system specification.

Sealing Cord
Sealing of flexible connection joints, executed as F90 in accordance with DIN 4102, meeting the required fire resistance class and system specification.

We realise customised special solutions for industrial and structural engineering systems as well as special constructions, including hard and soft bulkheads in building technology and spray coatings in operational systems. For us, project-specific engineering, quality assurance, documentation as well as monitoring and assessment by an independent testing centre are a matter of course - for every type of building, structure and industry.

Our expertise includes both the installation of our own products, such as the Lindner Fireport, and the installation of third-party products, such as Promat. Thanks to our comprehensive Lindner research and development, we are able to develop the optimum concept for every project and cover almost 100% of the requirements that arise in the area of structural fire protection.

Project-specific engineering, quality assurance, documentation and independent monitoring and assessment by test centres are a matter of course for us. Let our trained and experienced fire protection specialists advise you.

Competence centre for fire protection

Don't hesitate to contact us!

References

Our Projects world wide

Once around the globe and back again to our home Arnstorf: With our construction projects we are represented almost everywhere! No matter whether new construction or renovation, whether interior fit-out, building envelope or insulation – our references consist of a colourful mixture full of new challenges and impressive results.