Fireshield

Inspection door I 90 for service shafts

The large-format Lindner Fireshield I 90 inspection door closes openings in service shafts securely: It keeps smoke and fire within the shaft for over 90 minutes. Individually for you, we produce Fireshields in all sizes and formats and up to a maximum outer frame dimension of 2,109 mm width x 2,579 mm height. We offer both, single-leaf and double-leaf inspection door elements for your construction project – with symmetrical or asymmetrical door leafs. There are hardly any limits in terms of surface design either: Fireshield is equipped with a special primer finish as a standard. Moreover, you can choose from HPL surfaces, veneers and RAL lacquers. If required, the inspection door can be adapted seamlessly to the installation shaft wall.

  • Fire resistance class I 90 according to DIN 4102-4
  • large formats
  • single- or double-leaf doors – asymmetrical door leafs possible
  • special primer finish
  • HPL, veneer or lacquer surface available
  • flush installation for a frameless look possible

Downloads

Downloads

Product Information

Dimensions
Fire protection
Sustainability
Surfaces
Technical Details

Don't hesitate to contact us!

Digital Service

Tender texts and DIN/VOB specifications

Building Portfolio

Public Areas: Entrance Areas, Escape Routes

Work: Common Rooms, Facilities for Meetings, Conventions and Conferences, Stage and Studio Rooms, Office buildings, Film- & Recording Studios, Data Centres, Broadcasting Rooms, Television Studios, Utility Rooms, Assembly Rooms, Administration Buildings

Education: Library Rooms, Research Rooms, School of Higher Education, Schools, Teaching, Class and Educational Rooms

Businesses, Recreation and Culture: Banks, Shopping Centres, Cinemas and Theatres, Concert Halls, Museums, Places of Assembly

Healthcare: Pharmacies (Production), Clinics and Hospitals

Hotels and Gastronomy: Restaurants and Canteens, Hotels and Resorts

Industry: Laboratories and Research Facilities, Production Facilities

Public Institutions: Court Houses, Government Buildings

Transport: Train Stations, Airports


Technical requirements

Fire Protection: Fire Resistance

Hygiene: Cleanable by vacuuming, Wipeable

Corrosion Protection: Interiors

Design: Laminate, Varnish, Gypsum

References

Our Projects worldwide

Once around the globe and back again to our home Arnstorf: With our construction projects we are represented almost everywhere! No matter whether new construction or renovation, whether interior fit-out, building envelope or insulation – our references consist of a colourful mixture full of new challenges and impressive results.